Purpose: to remove the products of combustion from the combustion space to the atmosphere
Fuel: oil, gas,solid
System marking according to EN 1856-1
Ø 80-300 mm,T450-N1-W-Vm-L50(050-100)-G50
Ø 350-450 mm,T450-N1-W-Vm-L50(060-100)-G75
Ø 500-600 mm,T450-N1-W-Vm-L50(060-100)-G100
Ø 80-300 mm,T600-N1-W-Vm-L50(050-100)-G100
Ø 350-450 mm,T600-N1-W-Vm-L50(060-100)-G150
Ø 500-600 mm,T600-N1-W-Vm-L50(060-100)-G200
T450⁰ C- maximum operating temperature
T600⁰ C- maximum operating temperature
N1- natural draught
W- wet operating conditions
Vm- resistant to corrosion
G- resistance to soot fire
50;75;100 - distance to combustible materials
100;150;200 - distance to combustible materials
Flue liner- L50-stainless steel 1,4404
Ø - 80-200 mm - 0,5; 0,6; 0,8;1,0 mm
Ø - 250-550 mm - 0,6; 0,8;1,0 mm
Ø - 600 mm -0,8; 1,0 mm
The outer pipe – stainless steel 1,4301
The outer pipe – painted stainless steel 1,4301
Insulation- injected mineral wool, thickness -50 mm.